01
Duct design and fabrication
GI ducting sized for low velocity, fabricated to the route we have set out on your ceiling plan rather than adjusted on the fly.
Adayar, Chennai 600020 · Working across Tamil Nadu since 2006
Ductable & package
Equipment hidden above the ceiling, air delivered where you want it. Ducted systems are the usual answer for restaurants, showrooms and halls, where nobody wants machinery on the wall.
A ducted system lives or dies on the ductwork, not the unit. Undersized ducting makes noise and starves the far end of the room. A diffuser layout copied from a symmetrical plan onto an asymmetrical room leaves a warm corner that no service visit will ever fix.
We set out the duct route and the diffusers against the actual reflected ceiling plan, size for a velocity that stays quiet, and insulate properly — which in Chennai humidity is as much about stopping condensation dripping through a false ceiling as it is about efficiency.
At the end the system gets balanced with instruments, not by feel, and we record the readings so there is something to compare against in three years.
Where this applies
Restaurants and banquet halls, retail showrooms, training rooms and auditoriums, clinics, and open office floors with a false ceiling.

Ductable & package
Scope
This is what goes into the quote. If something on your job is not on this list, it will be written in rather than assumed.
01
GI ducting sized for low velocity, fabricated to the route we have set out on your ceiling plan rather than adjusted on the fly.
02
Insulation applied and sealed so that humid air is not condensing on cold duct above a false ceiling — the usual cause of ceiling stains a year after handover.
03
Throw and spread worked out for the room shape, with returns positioned so the air actually circulates instead of short-cycling back.
04
Airflow measured and adjusted at each outlet, with the figures written down and handed over.
Common questions
Allow around 450 to 600 mm of void for the duct and insulation over the main runs, less at the branches. If the height is tight we will look at a flatter duct section or a different unit position before telling you it cannot be done.
Almost always duct velocity — the ducting is too small for the air being pushed through it. It can sometimes be improved with diffuser changes and fan speed, but if the trunk is undersized that is the real fix.
Yes. We open up only where we need to, work at night if the space is trading, and make good afterwards. It is slower than a bare shell, and the quote will say so.
Ductable for most commercial interiors. Package units suit large open volumes where the machine can sit outside or in a plant space and blow through a short duct run.
Send us the drawings, the tonnage, or just a photo of the plant room. We will come out, measure up and give you a written quote — no charge for the visit anywhere in Chennai.